Open-access Accuracy and reliability of inertial devices for load assessment during flywheel workout

Precisión y confiabilidad de los dispositivos inerciales para la evaluación de la carga durante entrenamiento con polea cónica

Precisão e confiabilidade dos dispositivos inerciais para avaliação da carga durante o treinamento com polia cônica

Abstract

There is currently an increase in inertial flywheel application in strength training; thus, it must be monitored by an accurate and reliable device. The present study tested: (1) the accuracy of an inertial measurement device (IMU) to correctly measure angular velocity and (2) its inter-unit reliability for the measurement of external load. The analysis was performed using Pearson Correlation and Intraclass Correlation Coefficient (ICC). The IMU accuracy was tested using Bland-Altman and the reliability with the coefficient of variation (CV). Ten elite-level football players performed ten series of 5 repetitions in a one-hand standing row exercise (5 series with each arm). A nearly perfect accuracy (ICC=.999) and a very good between-device reliability (Bias=-.010; CV=.017%) was found. IMU is a reliable and valid device to assess angular velocity in inertial flywheel workout objectively.

Keywords: technology; weightlifting; exercise; physical fitness; sports

location_on
Escuela de Ciencias del Movimiento Humano y Calidad de Vida, Universidad Nacional Universidad Nacional, Campus Benjamín Núñez, Escuela Ciencias del Movimiento Humano y Calidad de Vida, Heredia, Heredia, Costa Rica, Heredia, Costa Rica, CR, 86-3000, 2562-4779, 2261-0032 - E-mail: revistamhsalud@una.cr